Description

The Fluke 116 is a workhorse of a unit, especially if temperature is important to your job. The 116 trades the 10A current-measuring capability for a thermocouple probe, while still offering all the standard great features & reliability of a Fluke multimeter.

Features

  • Autoranging Voltage measurement (AC/DC), 600V
  • Resistance
  • Capacitance (up to 1000uF)
  • Frequency (100 to 50kHz)
  • Thermocouple (Type K) -40°C to 400°C
  • Low Impedance (Z) mode (reduces possibility of loading the circuit with the meter)
Fluke 116
HVAC Multimeter — Specifications

Measurement Range Resolution Accuracy ± ([% of reading] + [counts])
DC millivolts 600.0 mV 0.1 mV 0.5% + 2
DC volts 6.000 V 0.001 V 0.5% + 2
60.00 V 0.01 V
600.0 V 0.1 V
Auto volts 600.0 V 0.1 V 2.0% + 3 (dc, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms 600.0 mV 0.1 mV 1.0% + 3 (dc, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts1 true-rms 6.000 V 0.001 V 1.0% + 3 (45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
60.00 V 0.01 V
600.0 V 0.1 V
Continuity 600 Ω 1 Ω Beeper on < 20 Ω off > 250 Ω; detects opens or shorts of 500 µs or longer.
Ohms 600.0 Ω 0.1 Ω 0.9% + 2
6.000 kΩ 0.001 kΩ
60.00 kΩ 0.01 kΩ 0.9% + 1
600.0 kΩ 0.1 kΩ
6.000 MΩ 0.001 MΩ
40.00 MΩ 0.01 MΩ 1.5% + 2
Diode test 2.000 V 0.001 V 0.9% + 2
Capacitance 1000 nF 1 nF 1.9% + 2
10.00 µF 0.01 µF
100.0 µF 0.1 µF
9999 µF 1 µF
100 µF to 1000 µF 1.9% + 2
> 1000 µF 5% + 20
Lo-Z capacitance 1 nF to 500 µF 10% + 2 typical
Temperature2
(Type-K thermocouple)
−40 °C to 400 °C 0.1 °C 1% + 102
−40 °F to 752 °F 0.2 °F 1% + 182
AC µamps true-rms
(45 Hz to 500 Hz)
600.0 µA 0.1 µA 1.5% + 3 (2.5% + 3 > 500 Hz)
DC µamps 600.0 µA 0.1 µA 1.0% + 2
Hz (V or A input)3 99.99 Hz 0.01 Hz 0.1% + 2
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
50.00 kHz 0.01 kHz
Notes:
1 All ac voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. Because inputs below 1% of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.
2 Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3 Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.